SFP-5UD is a five-zone FACP (Fire Alarm Control Panel)

SKU : SFP-5UD is a five-zone FACP (Fire Alarm Control Panel)
The SFP-5UD is a five-zone FACP (Fire Alarm Control Panel) and the SFP-10UD(E) is a ten-zone FACP. These control panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional buildings. Both panels include built-in communicators for Central Station Service and remote upload/download. Each of these FACPs is compatible with System Sensor’s microprocessor-based i3 series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory “freeze” signal when the ambient temperature falls below the detector rating. Additionally, both the SFP-5UD and SFP- 10UD are compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches, and other normally-open contact devices. Refer to the Notifier Device Compatibility Document for a complete listing of compatible devices. Outputs include four NACs (Notification Appliance Circuits), three programmable Form-C relays (factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special application resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity.

Product description

The SFP-5UD is a five-zone FACP (Fire Alarm Control Panel)
and the SFP-10UD(E) is a ten-zone FACP. These control panels
provide reliable fire signaling protection for small to
medium-sized commercial, industrial, and institutional buildings.
Both panels include built-in communicators for Central
Station Service and remote upload/download.
Each of these FACPs is compatible with System Sensors
microprocessor-based i3 series detectors. These conventional
smoke detectors can transmit a maintenance trouble signal to
the FACP indicating the need for cleaning and a supervisory
freeze signal when the ambient temperature falls below the
detector rating. Additionally, both the SFP-5UD and SFP-
10UD are compatible with conventional input devices such as
two- and four-wire smoke detectors, pull stations, waterflow
devices, tamper switches, and other normally-open contact
devices. Refer to the Notifier Device Compatibility Document
for a complete listing of compatible devices.
Outputs include four NACs (Notification Appliance Circuits),
three programmable Form-C relays (factory programmed for
Alarm, Trouble, and Supervisory) and 24 VDC special application
resettable and nonresettable power outputs. The FACPs
supervise all wiring, AC voltage, battery level and telephone
line integrity.